F-815 Sterilisable pH Electrode

B2–LS104–020–M30

B5-13202-5T7

B5-11005-07-J

B2-LS103-015-M30

B4-21006-020-M10

B4-35005-020-M10

B4-41001-2T9-M10

B4-21005-015-M10

B4-35004-015-M10

B4-31024-8T9-B06

B4-31004-8T9-B06

B4-32023-5T7-B03

B4-21004-007-M10

B4-35002-005-M10

B4-31003-5T7-B06

B4-53004-020-M10

B4-22005-020-M10

B4-12004-020-M10

B2-LS202-020-M69

B5-11315-020

B5-11007-20-R

B4-82004-8T9-M27

B4-53003-015-M10

B4-22004-015-M10

B4-12003-015-M10

B4-44002-8T9-M27

B4-42002-8T9-M27

B4-72003-8T9-M27

B4-32005-8T9-B03

B4-32004-8T9-B03

B2-LS201-015-M69

B5-11314-015

B5-11006-15-R

B5-13103-8T9

B5-12103-8T9

B5-11355-07J

B4-21002-003-M10

B4-31002-2T3-B06

B4-35001-2T3-M06

B4-53002-007-M10

B4-22003-007-M10

B4-12002-007-M10

B4-32003-5T7-B03

B2-LS102-007-M30

B5-11313-007

B5-11004-07-R

B4-22002-005-M10

B5-11312-005

B5-11003-05-R

B5-13102-5T7

B5-12102-5T7

B5-11321-03J

B5-11002-03-J

B5-13201-003

B4-82002-2T7-G34

B4-82001-2T7-M18

B4-81003-2T9-M12

B4-81002-2T9-M10

B4-81001-2T3-M06

B5-51001-2T9-006

B4-53001-2T5-M10

B4-23001-2T9-M10

B4-22202-015

B4-22001-003-M10

B4-12001-2T5-M10

B4-44001-2T7-M18

B4-42001-2T7-M18

B4-72002-2T7-G34

B4-72001-2T7-M18

B4-32002-2T3-B03

B2-LS101-2T5-M30

B5-11311-2T3

B5-11001-03-R

B5-13101-003

B5-12101-003

The new F-815 offers the same form, fit and function as the F-615 with improved performance and USP Class VI materials. The unique construction methods used by Broadley-James allows this pH probe to exhibit virtually zero drift after steam sterilisation (SIP).

The T-Pull® style FermProbe® sterilisable pH electrode is designed to be used in bioprocess applications where CIP/SIP procedures are used. Built to withstand repeated steam sterilization cycles, the FermProbe quickly stabilizes after steam exposure to be back on-line in half the time of other electrodes.

This electrode design specifies that the sterilisable pH electrode be secured to the housing by a free-spinning threaded retainer nut. This allows the electrode to be installed or
removed from the housing without twisting or disconnecting the electrode cable. Additionally, the T-Pull handle eases installation and removal of the electrode from the sensor housing.

The Model F815 FermProbe has two built-in electrolyte chambers that act to protect and isolate the sensitive inner AgCl reference half-cell. This "double junction", dual-chamber design effectively prevents the most common failure modes of pH electrodes in biopharmaceutical applications.

T-Pull® Handle FermProbe Sterilisable pH Electrodes

The T-Pull handle eases installation and removal of the electrode from the housing. The sterilisable pH electrode can be easily removed from the housing without being rotated or twisting the cable. This greatly reduces cable fatigue.

Features

  • Rugged handle design eases removal of electrode from housing. No tools required.
  • Greatly reduces cable fatigue.
  • Electrode retainer nut is part of the handle. Cannot be lost or misplaced.

Specifications

FermProbe pH Electrode Specifications:

  • 0 - 14 pH range
  • Steam sterilizable to 135° C
  • 150 psig max. pressure
  • Double junction, Ag-AgCl reference system
  • Electrode secures to housing with threaded retainer nut

Choose Electrode Length

If you have already chosen a sensor housing, select an electrode length with the same Class designation as the housing. The housing ordering information box also lists the correct electrode length to order. If you have not already chosen the housing, please review the recommendations next to each electrode model below.

Confirm Cable Length and Connector

Model F-815 pH electrodes require a disconnect cable and connector assembly (see Accessories tab for information about compatible cables).

Ordering Information

Model F-815 pH FermProbe with T-Pull Handle & Disconnect Cap

Electrode Model Class Use with these Housing Models Electrode Length Cable Length Connector Electrode Part Number
F-815 A 320326350, 370 110 mm Order Separately (See Accessories tab) F-815-B110-DH
F-815 A 320, 330, 326, 336, 350, 357, 370 130 mm F-815-B130-DH

Recommended Housings

The F-815 pH Electrode has a metric Pg13.5 threaded polymer cap allowing it to be used with European style housings. We recommend the following Broadley-James sensor housings for use with the FermProbe F-815 sterilisable pH electrode:

Compatible Cables

The T-Pull style F-815 pH Electrode uses a standard S8 detachable cable connection. We recommend the following cables for use with it:

Cable Type Sensor Connector & Device Connector Device Terminal
HP Plug to BNC Plug, Type A s8 cable bnc small bnc-jack
HP Plug to BNC Plug, Type M s8_cable-bnc-m-small bnc-jack
HP Plug to DIN Plug, Type M s8_cable-din-small DIN-jack
 HP Plug to Crimped Ferrules, Type M  s8_cable-ferrules-m-small  terminal-block
 HP Plug to Ferrules, Solution Ground, Type N
 s8_cable-ferrules-n-small  terminal-block