F-635 Autoclavable pH Electrode

B2–LS104–020–M30

B5-13202-5T7

B5-11005-07-J

B2-LS103-015-M30

B4-21006-020-M10

B4-35005-020-M10

B4-41001-2T9-M10

B4-21005-015-M10

B4-35004-015-M10

B4-31024-8T9-B06

B4-31004-8T9-B06

B4-32023-5T7-B03

B4-21004-007-M10

B4-35002-005-M10

B4-31003-5T7-B06

B4-53004-020-M10

B4-22005-020-M10

B4-12004-020-M10

B2-LS202-020-M69

B5-11315-020

B5-11007-20-R

B4-82004-8T9-M27

B4-53003-015-M10

B4-22004-015-M10

B4-12003-015-M10

B4-44002-8T9-M27

B4-42002-8T9-M27

B4-72003-8T9-M27

B4-32005-8T9-B03

B4-32004-8T9-B03

B2-LS201-015-M69

B5-11314-015

B5-11006-15-R

B5-13103-8T9

B5-12103-8T9

B5-11355-07J

B4-21002-003-M10

B4-31002-2T3-B06

B4-35001-2T3-M06

B4-53002-007-M10

B4-22003-007-M10

B4-12002-007-M10

B4-32003-5T7-B03

B2-LS102-007-M30

B5-11313-007

B5-11004-07-R

B4-22002-005-M10

B5-11312-005

B5-11003-05-R

B5-13102-5T7

B5-12102-5T7

B5-11321-03J

B5-11002-03-J

B5-13201-003

B4-82002-2T7-G34

B4-82001-2T7-M18

B4-81003-2T9-M12

B4-81002-2T9-M10

B4-81001-2T3-M06

B5-51001-2T9-006

B4-53001-2T5-M10

B4-23001-2T9-M10

B4-22202-015

B4-22001-003-M10

B4-12001-2T5-M10

B4-44001-2T7-M18

B4-42001-2T7-M18

B4-72002-2T7-G34

B4-72001-2T7-M18

B4-32002-2T3-B03

B2-LS101-2T5-M30

B5-11311-2T3

B5-11001-03-R

B5-13101-003

B5-12101-003

The F-635 style can be used in either benchtop or production vessels and is available in a variety of lengths. Steam sterilizable and autoclavable.

This is the standard Broadley-James metric FermProbe connector. This FermProbe style has been used as a standard for years. It is designed to be used in bioprocess applications where CIP/SIP procedures are used. The F-635 Autoclavable pH Electrode will withstand multiple autoclaving or sterilisation cycles, however, an autoclave cap should be used when autoclaving the electrode.

Metric FermProbe F-635 autoclavable pH Electrode

This FermProbe autoclavable pH electrode style features a metric Pg13.5 threaded polymer cap that allows it to be used with European style electrode housings. Autoclavable as well as steam sterilisable, this style of pH FermProbe is the first choice for use with small autoclavable benchtop vessels. Available only in the disconnect cap style. Cables must be ordered separately (see the Accessories tab for compatible cables).

Features

  • Metric threaded cap is compatible with nearly all European designed bioprocess electrode housings.
  • Steam sterilisable and autoclavable.
  • First choice for use with small autoclavable vessels.
  • Available in variety of lengths for different insertion length requirements and applications.

Specifications

  • 0 - 13 pH range
  • Steam sterilisable to 135° C
  • 150 psig max. pressure
  • Double junction, Ag-AgCl reference system
  • Metric Pg13.5 threaded disconnect cap

Choose Electrode Model

If the electrode needs to fit an existing cable, check cable connector. If it has a male connector, an F-635 or F-835 FermProbe is required. Another guideline is to note the connector’s colour. If the cable connector is black, use the F-635 or F-835 Fermprobe.

Choose Electrode Length

Benchtop Applications

The electrode length is from the base of the cap to the tip of the electrode (the glass part of the electrode).

SIP Tank Applications

If you have already chosen an electrode housing, select an electrode length with the same Class designation as the housing. The housing ordering information box also lists the correct electrode length to order. If you have not already chosen the housing, please review the recommendations next to each electrode model below.

Confirm Cable Length and Connector

Model F-635 pH electrodes require disconnect cable and connector assemblies (see Accessories tab for compatible cable information).

Ordering Information

Model F-635 pH FermProbe with Standard Metric Cap

Electrode Model Use with these Housing Models or Benchtop vessel sizes Electrode Length Cable Length Connector Electrode Part Number
F-635 325, 335 Class D

<1L Vessel

120 mm Order Separately (See Accessories tab) F-635-B120-DH
F-635 325, 335 Class F

1-3L Vessel

200 mm F-635-B200-DH
F-635  3L-5L Vessel 225 mm F-635-B225-DH
F-635 7L-15L Vessel 325 mm F-635-B325-DH
F-635 15L-20L Vessel 420 mm F-635-B420-DH
F-635  Many other lengths available, contact for information XXX mm F-635-B480-DH

Note: the vessel sizes are for guidance only – check your own vessel dimensions or the length of the electrode you are replacing.

Recommended Housings

The F-635 pH Electrode has a metric Pg13.5 threaded polymer cap allowing it to be used with European style housings. We would recommend the following Broadley-James sensor housings for use with the  Model F-635 FermProbe® steam sterilisable and autoclavable pH electrode:

Compatible Cables

The F-635 Autoclavable pH Electrode uses a standard S8 detachable cable connection. We recommend the following cables for use with it:

Cable Type Sensor Connector & Device Connector Device Terminal
HP Plug to BNC Plug, Type A s8 cable bnc small bnc-jack
HP Plug to BNC Plug, Type M S8 pH cable to BNC connector bnc-jack
HP Plug to DIN Plug, Type M s8_cable-din-small DIN-jack
 HP Plug to Crimped Ferrules, Type M  s8_cable-ferrules-m-small  terminal-block
 HP Plug to Ferrules, Solution Ground, Type N
 s8_cable-ferrules-n-small  terminal-block