D430 (25mm Sartorius) Dissolved Oxygen Sensor

B2–LS104–020–M30

B5-13202-5T7

B5-11005-07-J

B2-LS103-015-M30

B4-21006-020-M10

B4-35005-020-M10

B4-41001-2T9-M10

B4-21005-015-M10

B4-35004-015-M10

B4-31024-8T9-B06

B4-31004-8T9-B06

B4-32023-5T7-B03

B4-21004-007-M10

B4-35002-005-M10

B4-31003-5T7-B06

B4-53004-020-M10

B4-22005-020-M10

B4-12004-020-M10

B2-LS202-020-M69

B5-11315-020

B5-11007-20-R

B4-82004-8T9-M27

B4-53003-015-M10

B4-22004-015-M10

B4-12003-015-M10

B4-44002-8T9-M27

B4-42002-8T9-M27

B4-72003-8T9-M27

B4-32005-8T9-B03

B4-32004-8T9-B03

B2-LS201-015-M69

B5-11314-015

B5-11006-15-R

B5-13103-8T9

B5-12103-8T9

B5-11355-07J

B4-21002-003-M10

B4-31002-2T3-B06

B4-35001-2T3-M06

B4-53002-007-M10

B4-22003-007-M10

B4-12002-007-M10

B4-32003-5T7-B03

B2-LS102-007-M30

B5-11313-007

B5-11004-07-R

B4-22002-005-M10

B5-11312-005

B5-11003-05-R

B5-13102-5T7

B5-12102-5T7

B5-11321-03J

B5-11002-03-J

B5-13201-003

B4-82002-2T7-G34

B4-82001-2T7-M18

B4-81003-2T9-M12

B4-81002-2T9-M10

B4-81001-2T3-M06

B5-51001-2T9-006

B4-53001-2T5-M10

B4-23001-2T9-M10

B4-22202-015

B4-22001-003-M10

B4-12001-2T5-M10

B4-44001-2T7-M18

B4-42001-2T7-M18

B4-72002-2T7-G34

B4-72001-2T7-M18

B4-32002-2T3-B03

B2-LS101-2T5-M30

B5-11311-2T3

B5-11001-03-R

B5-13101-003

B5-12101-003

D430 (25mm Sartorius) Dissolved Oxygen Sensor is designed specifically for use with Sartorius fermentation vessels which are longer and have a slightly different internal design. In order to seal properly, the o-ring on these sensors has been moved closer to the tip of the sensor. Also available as D435 with right-angled connector.

This Broadley-James D430 Dissolved Oxygen Sensor is designed for use with Sartorius fermentation vessels which are slightly longer than the standard length and have a different internal design. As such they need slightly different sensors, hence the D430 with straight connector and D435 with right-angled connector. In both of these sensors the o-ring has been moved closer to the tip in order to create a better seal.

The sensor fits directly into the vessel, eliminating the need for a housing, reducing contamination risks. Few accessories are required. The modular design allows quick replacement of any part, making it easy to maintain and repair the sensor. OxyProbe dissolved oxygen sensors carry a 1-year warranty.

Specification

  • 316L Stainless Steel
  • Serialised for traceability
  • RA32 finish with electropolish on wetted parts
  • External EPDM o-ring
  • Secured retainer ring

How to choose a sensor

  1. Confirm the vessel has a 25 mm Sartorius side port.
  2. Determine how far the sensor should extend into the vessel. For most process media, the minimum length is optimal. However, if the media is viscous and tends to coat the inner wall of the vessel, a longer length may provide better performance.
  3. Decide whether a right angle connector is preferred over a straight connector.
  4. Choose cable length and connector. All DO sensors require cable and connector assemblies.

It is important to maintain the sensors by inspecting and calibrating them regularly. The membrane cartridge should be checked and refilled prior to every use.

25 mm OxyProbe with Straight Connector for Sartorius Ports

Sensor Model Sensor Length Typical Insertion Length Sensor Part Number
D430 70mm 12.7mm (0.5″) D430-B070-PT-D9
D430 95mm 35mm (1.4″) D430-B095-PT-D9

Membrane Kits

Broadley-James offer a range of membrane kits to suit all our dissolved oxygen sensors. These include everything required to replace the membrane cartridge and internal o-rings. All kits include:

  • QC Certificate
  • Material Cert

The following membrane kits are suitable for use with the D430 Dissolved Oxygen Sensor:

Membrane Kit Example Image Kit Contents
Single cartridge kit for 19 & 25 mm DO Sensors

Part No. KC2501

DO sensor 25mm single membrane kit One 25 ml bottle of electrolyte. One membrane cartridge. One set of internal o-rings
Four cartridge kit for 19 & 25mm DO Sensors

Part No. KC2504

DO sensor 25mm 4 membrane kit One 25 ml bottle of electrolyte. Four membrane cartridges. Four set of internal o-rings
25 Piece cartridge kit for 19 & 25mm DO Sensors

Part No. KC2525

 25mm-25piece 25 membrane cartridges in one easy-to-store box. Internal o-rings, gaskets and electrolyte must be ordered separately.

Compatible Cables

The D430 DO Sensor uses a D4 connector. This industry standard connector was the first, and is still, the best choice for DO sensors. We recommend the following cables for use with the D430 Dissolved Oxygen sensor:

Cable Type Sensor connector & Device Connector Device Terminal
D4 plug to Lemo 6 lemo6-d lemo6
DO Cable D4 to Crimped Ferrules crimp-d terminal-block

The internal seals of an Oxyprobe are all mechanical seals using o-rings. There are no adhesives to leak or fail in process, making this a more rugged and reliable sensor. Replacing the cathode is also much easier and faster since there is no sealant to clean from the threads. No sealant also makes the job of replacing the cathode much faster and cleaner.