Upstream

B2–LS104–020–M30

B5-13202-5T7

B5-11005-07-J

B2-LS103-015-M30

B4-21006-020-M10

B4-35005-020-M10

B4-41001-2T9-M10

B4-21005-015-M10

B4-35004-015-M10

B4-31024-8T9-B06

B4-31004-8T9-B06

B4-32023-5T7-B03

B4-21004-007-M10

B4-35002-005-M10

B4-31003-5T7-B06

B4-53004-020-M10

B4-22005-020-M10

B4-12004-020-M10

B2-LS202-020-M69

B5-11315-020

B5-11007-20-R

B4-82004-8T9-M27

B4-53003-015-M10

B4-22004-015-M10

B4-12003-015-M10

B4-44002-8T9-M27

B4-42002-8T9-M27

B4-72003-8T9-M27

B4-32005-8T9-B03

B4-32004-8T9-B03

B2-LS201-015-M69

B5-11314-015

B5-11006-15-R

B5-13103-8T9

B5-12103-8T9

B5-11355-07J

B4-21002-003-M10

B4-31002-2T3-B06

B4-35001-2T3-M06

B4-53002-007-M10

B4-22003-007-M10

B4-12002-007-M10

B4-32003-5T7-B03

B2-LS102-007-M30

B5-11313-007

B5-11004-07-R

B4-22002-005-M10

B5-11312-005

B5-11003-05-R

B5-13102-5T7

B5-12102-5T7

B5-11321-03J

B5-11002-03-J

B5-13201-003

B4-82002-2T7-G34

B4-82001-2T7-M18

B4-81003-2T9-M12

B4-81002-2T9-M10

B4-81001-2T3-M06

B5-51001-2T9-006

B4-53001-2T5-M10

B4-23001-2T9-M10

B4-22202-015

B4-22001-003-M10

B4-12001-2T5-M10

B4-44001-2T7-M18

B4-42001-2T7-M18

B4-72002-2T7-G34

B4-72001-2T7-M18

B4-32002-2T3-B03

B2-LS101-2T5-M30

B5-11311-2T3

B5-11001-03-R

B5-13101-003

B5-12101-003

SingleSense®

SU100-16

Single-Use Gas Well for Preinstallation in BPC

The SU100-16 is a single-use, gamma sterilizable gas well designed for preinstallation in bioprocessing containers (BPC) using a 1‑inch hose barb port.

Category:
Gas well features a steel mesh reinforced gas permeable membrane rated up to 30 psig
Membrane provides a sterile barrier, eliminating the risk of sensor damage from steam sterilization or autoclaving
Gas well reduces risk of BPC media contamination from direct sensor insertion

The SU100-16 SingleSense® Single-Use Gas Well is gamma sterilizable and designed for preinstallation into a bioprocess container (BPC) with a 1‑inch hose barb port. The gas well has a silicone rubber membrane that is steel mesh reinforced and gas permeable to O2 and pCO2.

The rugged, reinforced membrane is rated to 30 psig. The membrane provides a sterile barrier, eliminating the need to sterilise the DO or pCO2 sensor by autoclave. Avoiding steam sterilization of the sensor greatly lessens the risk of sensor damage.

Sensor Specifications

Measurement Range Not applicable
Operational Temp. Range 15°–50° C [59°–122° F]
Storage Temperature 5°–35° C [41°–95° F]
Shelf Life 36 months
Post Gamma: 30 months
Gamma Tolerance Level 50 kGy
Sensor/Tubing Interface 1-inch Hose Barb
Sensor Connector Cable 8-pin Variopin

 

How to Purchase

Please review the product purchasing sheet for product specifications and purchasing information.

Contact our sales team for more information.

Technical Sales