Model MXD70 MultiParameter Transmitter

B2–LS104–020–M30

B5-13202-5T7

B5-11005-07-J

B2-LS103-015-M30

B4-21006-020-M10

B4-35005-020-M10

B4-41001-2T9-M10

B4-21005-015-M10

B4-35004-015-M10

B4-31024-8T9-B06

B4-31004-8T9-B06

B4-32023-5T7-B03

B4-21004-007-M10

B4-35002-005-M10

B4-31003-5T7-B06

B4-53004-020-M10

B4-22005-020-M10

B4-12004-020-M10

B2-LS202-020-M69

B5-11315-020

B5-11007-20-R

B4-82004-8T9-M27

B4-53003-015-M10

B4-22004-015-M10

B4-12003-015-M10

B4-44002-8T9-M27

B4-42002-8T9-M27

B4-72003-8T9-M27

B4-32005-8T9-B03

B4-32004-8T9-B03

B2-LS201-015-M69

B5-11314-015

B5-11006-15-R

B5-13103-8T9

B5-12103-8T9

B5-11355-07J

B4-21002-003-M10

B4-31002-2T3-B06

B4-35001-2T3-M06

B4-53002-007-M10

B4-22003-007-M10

B4-12002-007-M10

B4-32003-5T7-B03

B2-LS102-007-M30

B5-11313-007

B5-11004-07-R

B4-22002-005-M10

B5-11312-005

B5-11003-05-R

B5-13102-5T7

B5-12102-5T7

B5-11321-03J

B5-11002-03-J

B5-13201-003

B4-82002-2T7-G34

B4-82001-2T7-M18

B4-81003-2T9-M12

B4-81002-2T9-M10

B4-81001-2T3-M06

B5-51001-2T9-006

B4-53001-2T5-M10

B4-23001-2T9-M10

B4-22202-015

B4-22001-003-M10

B4-12001-2T5-M10

B4-44001-2T7-M18

B4-42001-2T7-M18

B4-72002-2T7-G34

B4-72001-2T7-M18

B4-32002-2T3-B03

B2-LS101-2T5-M30

B5-11311-2T3

B5-11001-03-R

B5-13101-003

B5-12101-003

  • Up to 3 measured parameters with associated temperature readings can be displayed together
  • Can be expanded up to 6 relay control or alarm outputs and 6 isolated 4-20mA current outputs for recording or data logging
  • Simple intuitive menus displayed on a large backlit LCD.
  • IP66 compact 96 DIN Panel Mount or Surface/ Pipe Mount Versions
  • SD Card interface enables trouble free backup of configuration and simplifies software updates
  • Optional on-screen data trending and data logging to SD Card
Categories: ,

Features & Benefits

This versatile, compact instrument can be used to measure and control any combination of inputs from pH, redox, dissolved oxygen or conductivity sensors, with their associated temperature sensors. Relays and current outputs can be assigned to any measurement of choice.

pH and Redox Input

By providing the user with the flexibility to use virtually any pH electrode system, with single ended or differential inputs, means a single instrument can be used for the majority of pH measurement and control applications. Temperature compensator selection can be manual or automatic utilising Pt100 or Pt1000 temperature sensors. Simultaneous display of pH, temperature and electrode mV enables the user to determine sensor performance and process state.

Dissolved Oxygen Input

Simple configuration of the dissolved oxygen sensor type, means this instrument can be used with virtually any polarographic or galvanic dissolved oxygen sensor. Parameters such as membrane co-efficient, polarisation voltage and temperature compensator type, can be easily programmed into the instrument. Or for quick setup, a choice of popular default settings can be selected. Simultaneous display of dissolved oxygen in % saturation or partial pressure, raw probe output in nA and temperature, provides the user with all of the information needed to determine sensor performance and process state.

Conductivity & Resistivity Input

A choice of either contacting conductivity cell input, or electrodeless conductivity sensor input, enables this instrument to measure from ultra pure water quality to concentrated acids and alkalis. The measurement units can be displayed as resistivity (MΩ.cm) or conductivity (µS/cm). Built in algorithms allow the unit to interpret conductivity as concentration of acids and alkalis in % concentration (wt/vol). Automatic temperature compensation is applied to the measurement as an adjustable linear slope or full ultra pure water compensation.

Type No. Part No. Description
Base Unit
MXD73 7307  MXD73 Series IP66 Panel mounted base instrument fitted with 1 x 4-20mA current output and 2 x relay outputs. Requires 85-265v supply. Input cards and output expansion cards to be ordered separately.
MXD75 7507 MXD75 Series IP66 Surface mounted base instrument fitted with 1 x 4-20mA current output and 2 x relay outputs. Requires 85-265v supply. Input cards and output expansion cards to be ordered separately.
MXD73 7327 MXD73 Series IP66 Panel mounted base instrument fitted with 1 x 4-20mA current output and 2 x relay outputs. Requires 18-32v supply. Input cards and output expansion cards to be ordered separately.
MXD75 7527 MXD75 Series IP66 Surface mounted base instrument fitted with 1 x 4-20mA current output and 2 x relay outputs. Requires 18-32v supply. Input cards and output expansion cards to be ordered separately.
Input Card Options
MXD70CC  1001 Contacting conductivity input card
MXD70EC  1201 Electrodeless conductivity input card
MXD70PR  2002

pH/ORP (Redox) SensorTalkTM input card

MXD70DO  4003

Dissolved Oxygen SensorTalkTM input card

MXD70AUX  5001 Auxilliary mA input card
Expansion Card Options
MXD701I2R  7012 1 x Current output / 2 x Relay output expansion card
MXD703I  7030 3 x Current output expansion card
MXD703I4R  7034 3 x Current output / 4 x Relay output expansion card
MXD705I2R  7052 5 x Current output / 2 x Relay output expansion
MXD70MB  7104 MODBUS/4 relays output expansion
Data Logging & Live Trending
DATALOG  7000 Data logging and live trending firmware (unlock code)
Expansion Kits for use with MXD75 Surface Mount Chassis
MXD75EK1  7501 MXD75 Expansion kit 1 for use with expansion cards 7012, 7030, 7034 (For 3 inputs or any outputs)
MXD75EK2  7502 MXD75 Expansion kit 2 for use with expansion card 7052
  • Analog signal
  • Current is proportional and scalable to sensor signal
  • Carries one measured variable in one direction
  • Historical standard for measurement & control

The standard analog communication protocol for over 20 years. The primary variable is transmitted via a 4-20 mA current loop from the field device to the control system. Only one variable can be transmitted per loop. No secondary data is available for the control system, and the field devices can only be calibrated and configured at the device itself in the fermentation or cell culture suite.