NEW
Downstream

B2–LS104–020–M30

B5-13202-5T7

B5-11005-07-J

B2-LS103-015-M30

B4-21006-020-M10

B4-35005-020-M10

B4-41001-2T9-M10

B4-21005-015-M10

B4-35004-015-M10

B4-31024-8T9-B06

B4-31004-8T9-B06

B4-32023-5T7-B03

B4-21004-007-M10

B4-35002-005-M10

B4-31003-5T7-B06

B4-53004-020-M10

B4-22005-020-M10

B4-12004-020-M10

B2-LS202-020-M69

B5-11315-020

B5-11007-20-R

B4-82004-8T9-M27

B4-53003-015-M10

B4-22004-015-M10

B4-12003-015-M10

B4-44002-8T9-M27

B4-42002-8T9-M27

B4-72003-8T9-M27

B4-32005-8T9-B03

B4-32004-8T9-B03

B2-LS201-015-M69

B5-11314-015

B5-11006-15-R

B5-13103-8T9

B5-12103-8T9

B5-11355-07J

B4-21002-003-M10

B4-31002-2T3-B06

B4-35001-2T3-M06

B4-53002-007-M10

B4-22003-007-M10

B4-12002-007-M10

B4-32003-5T7-B03

B2-LS102-007-M30

B5-11313-007

B5-11004-07-R

B4-22002-005-M10

B5-11312-005

B5-11003-05-R

B5-13102-5T7

B5-12102-5T7

B5-11321-03J

B5-11002-03-J

B5-13201-003

B4-82002-2T7-G34

B4-82001-2T7-M18

B4-81003-2T9-M12

B4-81002-2T9-M10

B4-81001-2T3-M06

B5-51001-2T9-006

B4-53001-2T5-M10

B4-23001-2T9-M10

B4-22202-015

B4-22001-003-M10

B4-12001-2T5-M10

B4-44001-2T7-M18

B4-42001-2T7-M18

B4-72002-2T7-G34

B4-72001-2T7-M18

B4-32002-2T3-B03

B2-LS101-2T5-M30

B5-11311-2T3

B5-11001-03-R

B5-13101-003

B5-12101-003

SingleSenseTM

B2030-120-V8

OptaProbe™ Optical DO Sensor
for SU100 Series BPC Gas Wells

The B2030 is an optical dissolved oxygen (DO) sensor designed for use with SU100 series BPC gas wells. The sensor measures DO continuously from behind the gas well’s steel reinforced gas permeable membrane.

Category:
Sensor works behind sterile barrier of any SU100 series BPC gas well; does not need to be sterilized
Avoiding the need to insert the sensor directly into the BPC reduces the risk of BPC media contamination
The B2030 can be removed mid-run for calibration check if needed

The B2030 is an optical dissolved oxygen (DO) sensor with a domed measuring surface designed and optimised for use with SU100 series BPC gas wells. The sensor performs continuous measurement behind the rugged, sterile, steel-mesh reinforced membrane barrier of the gas well, eliminating the need to heat sterilise the sensor. The sensor has no wetted materials as the gas well prevents the sensor from direct contact with the BPC media.

The B2030 digital output is compatible with SensorTalk™ input DO transmitters and similar instrumentation. The sensor output can be converted to Modbus RTU with a SmartSync™ signal conditioner. Additionally, the digital output can be converted to nanoamp output with the OptaSync™ signal conditioner.

The B2030 threads directly into any SU100 series BPC gas well using the sensor’s Pg13.5 threaded fitting. Hand tightened. No tools needed.

Sensor Specifications

Measurement Range 0–300% SAT
Operational Temp. Range 5°–50° C [41°–122° F]
Pressure Range 0–3750 mmHg [0–72 psig]
Response Time: T98 < 15 seconds at 37° C; N2 to AIR
T98 < 15 seconds at 37° C; AIR to N2
Accuracy Within 1% full scale (% SAT)
Sterilization Temperature Not heat sterilizable. For use only with SU100 series single-use BPC gas wells.
Insertion Length 120 mm
Sensor/BPC Gas Well Interface Pg13.5 Threads
Sensor Connector 8-pin Variopin
Sensor Output
  • SensorTalk™, RS232 to Transmitter
  • Modbus RTU (with SmartSync™)
  • nAmp output (with OptaSync™ Module)
Power Supply 5 VDC supplied by SmartSync™ or transmitter
Storage Temperature 5°–35° C [41°–95° F]
Shelf Life 48 months (optical membrane)

 